PASSION ENTHUSIASM REACHING NEW HEIGHTS

AUTHORIZED DISTRIBUTOR OF TELEVIC CONFERENCE PRODUCTS IN VIETNAM          AUTHORIZED DISTRIBUTOR OF AMBIENT PUBLIC ADDRESS PRODUCTS         SYSTEM INTERGRATORS OF ELV, CCTV CAMERA, PUBLIC ADDRESS, ACCESS CONTROL SYSTEMS

Perimeter security, CCTV and access control system
Conference system, Projectors, Dedicated Screens
Public address, Prosound, Stage lighting system
PABX, LOCAL IT SYSTEM
Other systems & Sollutions
HỖ TRỢ KHÁCH HÀNG
  • Support 01
    0913.211.510
  • Support 02
    0778.368.986
web site hit counter
Products \ Perimeter security, CCTV and access control system \ Access control system \ HONEYWELL \ NX1MPS Controller
NX1MPS Controller
Features
Configurations
Manuals

Features:

·       SIMPLE: Manage your access control anywhere with an Internet connection

·       SCALABLE: Purchase the exact amount of access control you need now and easily add doors later

·       FLEXIBLE: Compatible with WIN-PAK ® SE, WIN-PAK PE and WIN-PAK PRO CS (managed access) software

Configuration:

·       Door/Reader Capability

1, 2 or 3 DOOR Controller (NXD1 or NXD2 add-on board is  required for 2nd or 3rd door)

·       Expandability

Expandable up to 93 DOORS (186 readers) per controller loop

·       Dual Reader Control Capability (IN/OUT Reader per Door

IN and OUT reader capability per door (readers must have HOLD line capability)

·       Reader Compatibility

Standard Wiegand protocol supported ABA not supported

Outputs:

 

·       Number of Outputs

Two SPDT relays (jumper selectable NO or NC contacts) per door rated at 3 A @ 28 VDC. Two open collector outputs (OC) (16 ma, 12 VDC): reader LED (Aux) and reader buzzer (Aux) per door are available

·       Output Expandability

2-door solution has 8 total outputs: 4 relays, 4 OC (requires NXD1 add-on board)

3-door solution has 12 total outputs: 6 relays, 6 OC (requires NXD2 add-on board)

·       Relay Power Source

Selectable: +12 VDC self-powered - OR -0 to 28 VDC externally supplied source

Inputs:

 

·       Number of Inputs

Controller has a total of six configurable four-state supervised input points.

(Factory default settings are Status, REX, Reader Tamper A, Reader Tamper B, Power Fail and General Input)

·       Input Expandability

2-door solution has a total of  10 inputs (requires NXD1 add-on board). 3-door solution has a total of 14 inputs (requires NXD2 add-on board

·       Power-Fail and Panel Tamper

Yes

Power input:

 

·       Unit Input

93 VAC to 264 VAC, 50/60 Hz input provides 12 VDC, 4 A output

·       Socket or Hardwire AC Input

Yes

·       Control Board Power Input

+12 VDC from included power supply

Power Output:

 

·       Power for Reader(s) and Input Devices

1.15 A per door for locks/strikes, readers and input devices (3.5 A @ 12 VDC total)

·       Backup Battery System

12 VDC, 7 AH battery

Enclosure:

 

·       Material

Metal

·       Dimensions:

13.9"H x 11.9"W x 4.7"D

·       Wiring Access Holes/Knockouts

19

Installation:

 

·       Removable Terminal Blocks with Color Coded Labels

Yes

·       Graphic Wiring Cards / Labels

Yes

System information

 

·       Real time clock

Global Geographic Time Zone Support

Daylight Saving Time Support

·       Clock synchronization

Yes - via NTP network server

·       Processor:

Freescale coldfire 32-bit

·       System MTBF (mean time between failures)

250,000 hours

·       Temperature Ratings

32 to 120˚F (0˚C to 49˚C) Operating

-67 to 185˚F (-55˚C to +85˚C) Storage

·       Certifications and Approvals

CE and FCC compliant, UL-294 listing pending

LED:

 

·       Led status

12 LEDs total (12V power, PoE, over current, Ethernet, RS485, reader(s),

door state, run, relay status)

Comms

 

·       Built-inCommunication Options

Ethernet, USB 8, RS485

·       Controller Loop Capability

Total of 31 panels in a loop

Host

 

·       Software Compatibility

WIN-PAK SE, WIN-PAK PE, WIN-PAK PRO CS, WIN-PAK CS 4.1

WIN-PAK 2005, WIN-PAK PRO 2005, WIN-PAK 2.0 Release 4, WIN-PAK PRO Release 4

·       using PCI3 Converter

Supported downstream panels include NetAXS-123, NetAXS-4, N-1000 family and NS2

·       using N-485-PCI-2 Converter

Not compatible with NetAXS-123 or NetAXS

Door Control:

 

·       Door Control Modes

Card only, card and PIN, card or PIN, PIN only, lockdown, disabled, supervisor, escort, limited use card, expire on date, first card rule, snow day rule, time zone toggle, anti-passback, duress

·       Interlocks for custom actions

Yes

CARDS and DATABASE

 

·       Card and Event Buffer Capacity

10,000 card capacity, 25,000 event capacity

·       Offline Database backup available

Card and configuration databases

·       Number of Card Formats

128 unique card formats can be supported

·       Maximum Card Format Size

75-bit

·       Time Zones

127

·       Access Levels

128

·       Holidays

255

Reporting and analysis

 

·       Integrated basic reports

Yes

·       Import/export of card database

Yes

·       Alarms and events can be exported and saved In offline storage

Yes

EMBEDDED WEB SERVER

 

·       Supported Browsers

Internet Explorer and Mozilla Firefox

·       Web Server Support

All access control functions

·       Secure Web Browsing

SSL và SHA-1

·       Multiple user connections

Yes